PG-Smatank 1,

Overfill-Alarm,

Smartank Alarms are available as Mains, Battery or Dual (mains and/or battery)

The PSU is enclosed in a separate enclosure.
12v, 24v, and 240v

Technical Specification:

Sounder  2600HZ 90db @ 0.3M

Dimensions (LxDxH)  105x98x107mm

Test Button Standard

IP Rating  IP 55

Probe material  Nylon 6.6 with Brass Weight

 

 

 

Waste Oil Gauge

Displays Your Waste Oil level in your tank.

 

 

NEW in FEB 2009

 

Please contact our distributors for price

UNIVERSAL REMOTE TANK LEVEL GAUGE  See your tank level indoors whatever type of tank you have!  WatchmanNiveau is ideal for retrofitting to any existing tank!

 One size fits all design is easier to install with its unique self-calibrating tube technology  

• Standard 1,000 metre range • Proven five year battery life • No moving parts • No probe required • Shows tank level in 1/10ths • Low tank level warning • In-built overfill alarm • Compatible with telemetry*

The complete tank and bund monitoring system. Watchman Plus – the most complete tank monitor yet! Watchman Plus is a revolutionary wireless solution allowing remote monitoring on both the tank level and the tank bund area.

 

ULTRASONIC TANK LEVEL MONITOR, One model fits all, Quick and easy to install, Suitable for steel or plastic tanks, 12 months replacement guarantee, Low power consumption, 200 metre transmitter to receiver range,

Measures tanks up to 3 meters in height

 

Watchman Niveau,

Please contact our distributors for price

Please contact our distributors for price

Watchman Plus,

Please contact our distributors for price

Active Rain,

Dit 1 - Dit 1e -  tank contents indicator consists of an electronic pressure sensor and a microprocessor-controlled indication system contained in a sturdy plastic housing. The measured values are shown on a 4 digit liquid crystal display (LCD). The function key F allows you to switch on the device and select the display modes litres, cubic metres, percentage and filling level.

 

 

 

 

 

 

 

 

Dit 2 - Specially suitable gauge for continuous level measurement in rain water tanks and cisterns. For liquid levels from 1 to 4 m.

Universal, pneumatic tank contents gauge featuring capsule type movement for remote indication up to 50 m. Accuracy for measurement ±2 % FSD. Zero correction and overpressure protection device. Fully adjustable for tank heights between 900 and 3,000 mm at a density of 0.84 g/cm³ (fuel oil and diesel). Reference pointer and date indicator for easy consumption control. Impact resistant plastic housing for wall mounting.

 

Please contact our distributors for price

Dit 2,

Please contact our distributors for price

Unitop,

Universal mechanical level gauge fitted with a high quality brass mechanism, adjustable for tanks with heights or diameters between 90 and 200cm. The only gauge with litre scale facility.

 

Measures tanks up to 3 meters in height

 

Please contact our distributors for price

MTF 2000,
Unimes E,

Continuous tank contents indication in tanks containing light heating oil EL, diesel and other low viscosity liquides which do not attache the materials of the gauge. For tank heights from 900 to 2000mm.

 

Please contact our distributors for price

Dit 1 & Dit 1 e,

new

The wireless solution to interceptor control

 

The Interceptor Watchman is a revolutionary wireless solution allowing remote notification of the need to have an underground interceptor tank emptied. Benefits include –

Easily fitted to existing tanks Excellent operational range Updates every six seconds Require no wiring uses radio connection Up to four years battery life Visual and audible alarm

Compatible with Signalman for connection to telemetry for automatic emptying

1

A sensor and a radio transmitter are fitted to the

monitored every 6 seconds to check if oil has been detected at the level where the interceptor requires emptying.

underground tank. The tank alarm remains on until the tank has been emptied.

2

The signals are received by the control unit and

alarm sounds and a light is shown when the tank needs to be emptied.

alarm display inside. An

3

When the ‘Acknowledge’ button is pressed, the

audible alarm stops. The visual

alarm remains on until the tank has been emptied.

MULTI-LEVEL ALARM

 

FEATURES

● ALL FEATURES AND OPTIONS OF STANDARD ALARMS APPLY

● MAINS POWER HEALTHY INDICATOR  

● NO NEED TO REPLACE BATTERIES

● LARGE FLASHING RED LED INDICATOR ALERTS WITH SOUNDER WHEN TANK IS LOW OR FULL  

● AVAILABLE IN 240V, 110V AC OR 24V DC

● RETAINS LEVEL DURING POWER FAILURE  

●5 LEVELS INDICATED

 

TECHNICAL SPECIFICATION

 

POWER REQUIREMENTS: 240V AC●

SIMPLE TO INSTALL

DIMENSIONS (L X D X H) 147 X 110 X 215MM

ENCLOSURE MATERIAL: POLY CARBONATE

RATING: IP55

TANK MOUNTING: STANDARD 1/ 2 " BRASS CAP

SOUNDER: 2600 HZ 90 DB @ 0.3

MATERIAL (PROBE): (LENGTH AND MATERIAL MUST BE SPECIFIED WITH ORDER)

 

                                                                          CODE

Mains Operated Multi-Level Alarm                          PGS  2005

Multi-Level Battery Version                                   PGS  2105

Multi-Level Probe only                                          PGS  2005P

Extra Cable per mtr                                              PGS  1009

 

Please contact our distributors for price

Technical information
Technical information
Technical information
Technical information
Technical information
Technical information
Technical information
Technical information
Technical information
Technical information
Technical information
Home.
Fuel Gear.
Fuel Dispenser.
Fuel Parts & Accesories.
Level Gauges.
Flow Meter Systems.
Environmental Protection Applications .
Contact Us.
Technical information.